Product Identification

Product ID:MARINE CLEANER & DEGREASER (AEROSOL), 6020
MSDS Date:11/01/1985
FSC:6850
NIIN:00N075085
MSDS Number: CCTLT

Responsible Party
CRC CHEMICALS
885 LOUIS DR
WARMINSTER, PA 18974
US

Emergency Phone: 215-674-4300

Info Phone: 215-674-4300

Preparer: A.P. REED

Cage: CRCCE

Contractor
CRC INDUSTRIES, INC.
WARMINSTER, PA 18974-2820 US

Telephone: 215-674-4300/800-424-9300

Cage: 10136

Ingredients

ETHANE, 1,1,1-TRICHLORO-; (1,1,1-TRICHLOROETHANE) (SARA

CAS: 71-55-6

RTECS: KJ2975000

Fraction By Weight: 72%

OSHA PEL 350 PPM

ACGIH TLV: 350 PPM;450 STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


ETHYLENE, TETRACHLORO-; (PERCHLOROETHYLENE) (SARA 313)

CAS: 127-18-4

RTECS: KX3850000

Fraction By Weight: 24%

OSHA PEL 100 PPM

ACGIH TLV: 25 PPM;100 STEL

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS


CARBON DIOXIDE

CAS: 124-38-9

RTECS: FF6400000

Fraction By Weight: 4%

OSHA PEL 5000 PPM

ACGIH TLV: 5000 PPM;30000 STEL

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:CHLOROCARBON MATLS HAVE PRDCD SENSIT
OF MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS & COULD HAVE SIMILAR
EFT IN HUMANS. ADRENOMIMETICS (E.G., EPINEPHRINE) MAY BE
CONTRAINDICATED EXCEPT FOR LIFE-SUSTAININ G USES IN HUMANS
ACUTELY/CHRONICALLY EXPOS TO CHLOROCARBONS .
ACUTE:INHALATION:HEADACHES, (EFTS OF OVEREXP)
Explanation of Carcinogenicity:TETRACHLOROETHYLENE:IARC MONOGRAPHS ON
EVAL OF CARCIN RISK OF CHEMS TO MAN, VOL 63, PG 159, 1995:GRP 2A.
NTP 7TH(SUPDAT)
Effects of Overexposure:HLTH HAZ:DIZZINESS, ANESTHESIA,
UNCONSCIOUSNESS. EYES:CAUSES PAIN & SOME IRRITATION. SKIN:CAUSES
IRRITATION ON REPEATED EXPOSURES. CHRONIC:REPEATED OVEREXPOSURES
MAY CAUSE LIVER & KIDNEY EFFECTS.
Medical Cond Aggravated by Exposure:HIGH LEVELS (8000 PPM +) OF VAPOR
MAY CAUSE CARDIAC ARRTHYMIAS.

First Aid

First Aid:IF SYMPTOMS PERSIST, CALL MD. INHAL:REMOVE TO FRESH AIR,
APPLY ARTIFICIAL RESPIRATION IF NECESSARY. EYES:FLUSH FOR AT LEAST
15 MINUTES W/LARGE AMOUNTS OF WATER. SKIN:REMOVE CONTAMINATED
CLOTHING. WASH EXPOSED SKIN W/SOAP. INGEST:DO NOT INDUCE VOMITING
- CALL MD.

Fire Fighting

Flash Point Method:TCC
Flash Point:NONE
Lower Limits:7.5%
Upper Limits:14.5%
Extinguishing Media:WATER FOG.
Fire Fighting Procedures:WEAR NIOSH APPROVED PRESSURE DEMAND SCBA &
FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:THERMAL DECOMPOSITION PRODUCTS MAY
INCLUDE HCL & PHOSGENE . AEROSOLS MAY EXPLODE IF THEIR TEMPERATURE
EXCEEDS 130F.

Accidental Release

Spill Release Procedures:USUALLY NOT A PROBLEM W/AEROSOLS - AREA SHOULD
BE VENTILATED & ABSORBENT USED TO PICK UP EXCESS MATERIAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:AVOID PRLNG SKIN CONT/BRTHG OF VAPS.
SINCE VAPS ARE HVR/AIR, AEROSOLS SHOULD NOT BE USED IN CONFINED
AREAS/LOW SPOTS W/OUT ADEQ VENT.
Other Precautions:NO SMOKING IN AREA OF USE. DO NOT USE IN GEN VICIN OF
ARC WELDING, OPEN FLAMES/HOT SURFS. HEAT &/OR UV RADIA MAY CAUSE
FORM OF HCL &/OR PHOSGENE . STORE IN COOL, DRY AREA. IF VAPS ARE
SUSPECTED IN LOW AREA, DO NOT ENTER UNLESS(SUPDAT)

Exposure Controls

Respiratory Protection:ABOVE TLV USE NIOSH APPROVED SELF CONTAINED AIR
MASK OR VAPOR MASK.
Ventilation:MAINTAIN VAPOR CONCENTRATION BELOW TLV - USE MECHANICAL
MEANS IF NECESSARY.
Protective Gloves:SOLVENT RESISTANT GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA . NOT NORMALLY REQUIRED FOR AEROSOL PRODUCTS.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXPLAN OF CARCIN:ANNUAL REPORT ON CARCINOGENS, 1994:ANTICIPATED TO BE
CARCINOGEN. ANIMAL:LIVER TUMORS. OTHER PREC:NIOSH APPROVED SPECIAL
BREATHING APPARATUS IS USED & OBSERVER IS PRESENT FOR ASSISTANC E.
KEEP AEROSOLS AWAY FROM HEAT.

Chemical Properties

Boiling Pt:B.P. Text:>165F,>74C
Vapor Pres:85
Vapor Density:4.8
Spec Gravity:1.385
Evaporation Rate & Reference:RAPID
Solubility in Water:SLIGHT SOLUBILITY
Appearance and Odor:COLORLESS LIQUID; IRRITATING ODOR AT HIGH
CONCENTRATION.
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
AVOID STORAGE IN ALUMINUM CONTAINERS OR CONTACT W/ALUMINUM OR ZINC
POWDER.
Stability Condition to Avoid:AVOID EXPOSURES TO OPEN FLAMES, ARCS &
HIGH TEMPERATURE.
Hazardous Decomposition Products:THERMAL - HYDROGEN CHLORIDE, CHLORINE
& SOME PHOSGENE.

Disposal

Waste Disposal Methods:DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL
REGULATIONS . DISCARDED FILLED CANS OR PARTIALLY USED CANS ARE
HAZARDOUS WASTE - DISPOSE OF IN CONFORMANCE TO REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,